Asymtek TC V3 Especificações Página 12

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 11
2-4 Safety
4. Reset the main circuit breaker inside the electronics enclosure if it has been tripped.
5. Turn the red EMO button clockwise until it pops back into position.
6. Remove all warning tags and locking devices.
7. Restart the Cure Module.
8. Wait at least 30 seconds then push the reset button. Failure to do so could cause problems
with the motor speed controller.
9. Open the Alarm window and reset alarms on the PLC. Refer to the TC V3 Operations Manual
for alarm reset procedures.
10. Click on the Start button on the Main Menu.
11. Wait for temperature stabilization before running production. The alarm sounds at start up.
Vista de página 11
1 2 ... 7 8 9 10 11 12 13 14 15 16 17 ... 39 40

Comentários a estes Manuais

Sem comentários